    Unless it gets very cold, probably no need to keep it. Had mine removed and I live in the UK. Not sure if there is anywhere that needs AC in summer and gets too cold for a heat pump in winter.

    • Captain Aggravated@sh.itjust.works
      link
      fedilink
      English
      arrow-up
      2
      ·
      7 hours ago

      Not an option. Two reasons:

      1. Emergency heat is a legal requirement. A heat pump system without a source of emergency heat does not meet the North Carolina residential building code. That law was written back when AC was newfangled and untrusted, and Raleigh (and many other state capitols) didn’t want families freezing to death because a compressor motor failed.

      2. American central HVAC systems are modular by nature, a heat pump system is designed to rely on the emergency heat system for defrost heat. Auto-defrost is accomplished by overriding the thermostat and commanding Emergency Heat ON, reversing valve to AC, compressor ON, fan ON. The ensuing sparring match between the heater and air conditioner pretty effectively defrosts the outdoor unit. And in the United States at least, by far the world’s largest producer of natural gas, it’s considerably less expensive to do that under methane power than electricity.

      Defrost is a critical feature in my climate; winter hovers around freezing, often climbing to 1 or 2C during the day and dipping to -3 or -4C at night, and the relative humidity is ALWAYS high. Perfect icing conditions for a heat pump.

      • livligkinkajou@slrpnk.net
        link
        fedilink
        arrow-up
        1
        ·
        4 hours ago

        Emergency heat is a legal requirement

        Isn’t that a requirement only applicable to health facilities, and one that you can also skip if you have two separate energy sources?

        • Captain Aggravated@sh.itjust.works
          link
          fedilink
          English
          arrow-up
          2
          ·
          4 hours ago

          Different concepts. This has nothing to do with “in case the power fails.”

          This has apparently changed since last I went shopping for a heat pump. Used to be, heat pumps couldn’t be expected to sufficiently heat a house on the coldest days of the year, so a second additional heat source would have to be installed, which also doubled as a backup in case the heat pump mechanically failed. The setting on the thermostat to engage this second heat source was labeled “Emergency Heat” or “EmHeat”, like so:

          A better term would probably be Auxiliary or Supplemental heat but the industry uses the term Emergency Heat.

          Apparently there are heat pump systems on the market now which can pass inspection on their own with no supplemental “emergency” heater. I suppose that goes hand in hand with the technology becoming more viable in the northern latitudes. They didn’t used to be suitable for colder climates but now they are, I guess that means they’re suitable for flying solo here. I wouldn’t personally do that because A. I like to have the backup in case of system failure, and B. without heat strips or a furnace, the defrost cycle is just…running the air conditioner. The source of defrost heat is your mammalian ass.

      • HerbGrower@slrpnk.net
        link
        fedilink
        arrow-up
        2
        ·
        6 hours ago

        Surely a heat pump can fail just as easily as a boiler? Log burner or even a biofuel fire kinda thing would be far more suitable as an actual emergency backup.

        • Captain Aggravated@sh.itjust.works
          link
          fedilink
          English
          arrow-up
          2
          ·
          4 hours ago

          So in my part of the country, boilers are oldfangled and fairly rare. I’ve never seen a new one installed during my lifetime. You will find them in the Northeast I gather. Recall that the United States is a huge territory with a dramatic range of climates; the several states vary their HVAC standards and practices to meet their conditions. I live in central North Carolina, these are the standards I know and shall speak on.

          In my locale, forced air HVAC is typical. No boiler, no hot water pipes, save for those run from a water heater to sinks, bathtubs, washers etc. The AC system necessary down here in sweet tea Cackalacky requires large air ducts from the evaporator to the living spaces, so if you’re going to install those, you might as well also use them for winter heat rather than plumb the house for an entirely separate boiler and radiators.

          The law I mentioned was written with all-electric systems in mind. The “emergency” heater is basically a big resistor; a coil of wire commonly called a “heat strip” and a contactor that connects it to 220v mains power. It’s like a toaster big enough for a man to crawl through. Mechanically simpler than a heat pump though less energy efficient, they’re intended to provide heat 1. in case the heat pump fails somehow, 2. on those “but sometimes” occasions where the temperatures dip below that which the heat pump is designed for (this used to be a bigger problem than it is now; 1960s era heat pumps were less effective in cold temperatures than modern ones), and 3. defrosting.

          My home has a furnace plus air conditioner system, I don’t currently have a heat pump. I have a forced air condensing furnace, I’ll let my main man Alec explain in detail how those work, and an air conditioner. The air conditioner is almost exactly like a heat pump except no reversing valve. The furnace serves as the air conditioner’s air handler, when the thermostat is set to air conditioning it sends a compressor ON signal to the air conditioner and a fan ON signal to the furnace. Switching to a heat pump system would mean wiring up the furnace as the “emergency heat” system.

          I live in a climate where a heat pump can almost provide for all heating needs, my father has a heat pump and furnace system, and in the deepest depths of winter the furnace runs about an hour a week, and a little more during those “but sometimes” cold snaps. We’re the United States, natural gas is abundant and cheap here, so it’s actually cheaper to use gas for backup heat than resistive electric.

          This all does assume that mains power is up and running. The true emergency backup, for when the power grid is down, is typically an entirely separate system chosen by the whims of the homeowner. I have a natural gas fired Glo-Warm, a mechanically operated radiant heater that requires no electricity. My father has a kerosene heater and keeps 10 gallons of kerosene in his tool shed. My uncle has a wood burning stove. My neighbor has a natural gas burning whole house generator. A couple work colleagues have rooftop solar and various degrees of battery backup. We’re in “what works for you personally” territory. Most of the Texans I know have no plan whatsoever and during that blizzard that hit them a few years ago they huddled around scented candles for warmth and shat in buckets. It’s a free country, do whatever you want.

      • SaveTheTuaHawk@lemmy.ca
        link
        fedilink
        English
        arrow-up
        1
        ·
        6 hours ago

        A heat pump system without a source of emergency heat does not meet the North Carolina residential building code.

        I lived in an NC apartment complex. When the power went out, we froze. There was no emergency heat.