• Captain Aggravated@sh.itjust.works
    link
    fedilink
    English
    arrow-up
    2
    ·
    2 hours ago

    Not an option. Two reasons:

    1. Emergency heat is a legal requirement. A heat pump system without a source of emergency heat does not meet the North Carolina residential building code. That law was written back when AC was newfangled and untrusted, and Raleigh (and many other state capitols) didn’t want families freezing to death because a compressor motor failed.

    2. American central HVAC systems are modular by nature, a heat pump system is designed to rely on the emergency heat system for defrost heat. Auto-defrost is accomplished by overriding the thermostat and commanding Emergency Heat ON, reversing valve to AC, compressor ON, fan ON. The ensuing sparring match between the heater and air conditioner pretty effectively defrosts the outdoor unit. And in the United States at least, by far the world’s largest producer of natural gas, it’s considerably less expensive to do that under methane power than electricity.

    Defrost is a critical feature in my climate; winter hovers around freezing, often climbing to 1 or 2C during the day and dipping to -3 or -4C at night, and the relative humidity is ALWAYS high. Perfect icing conditions for a heat pump.

    • livligkinkajou@slrpnk.net
      link
      fedilink
      arrow-up
      1
      ·
      8 minutes ago

      Emergency heat is a legal requirement

      Isn’t that a requirement only applicable to health facilities, and one that you can also skip if you have two separate energy sources?

    • HerbGrower@slrpnk.net
      link
      fedilink
      arrow-up
      2
      ·
      2 hours ago

      Surely a heat pump can fail just as easily as a boiler? Log burner or even a biofuel fire kinda thing would be far more suitable as an actual emergency backup.

    • SaveTheTuaHawk@lemmy.ca
      link
      fedilink
      English
      arrow-up
      1
      ·
      2 hours ago

      A heat pump system without a source of emergency heat does not meet the North Carolina residential building code.

      I lived in an NC apartment complex. When the power went out, we froze. There was no emergency heat.